ARKRAY USA

Safe. Easy to use. Cost effective.

Assure® ID Safety Pen Needles, from the brand you trust for safety and quality, offer features you require at a more cost-effective price than the market leaders.
Assure® ID Safety Pen Needles are now available in two models: Assure ID DUO PRO (with back-end shield) and Assure ID PRO (without back-end shield).

Features

SIZE

5mm

Assure® ID
Safety Pen Needles

SAFETY BEFORE

  • ClearPrime™ safety cover allows view of priming drops to ensure safe operation and delivery
  • Clear shield covers needle before injection to prevent needle exposure

SAFETY AFTER

  • Front-end safety shield to help protect against accidental needle sticks
  • Back-end safety shield to help protect against accidental needle sticks (Assure ID DUO PRO Safety Pen Needle only)
  • Red indicator to signal the safety shield has activated

COMFORT

  • Needle lubrication designed to support smooth injections
  • Tri-bevel needle for comfortable injections

UNIVERSAL FIT

  • Fits securely to major pen devices from leading manufacturers, including:
    • Sanofi Aventis: ClikSTAR®, SoloSTAR®, JuniorSTAR®
    • Lilly: KwikPen®, HumaPen® Memoir, HumaPen® Luxura HD, HumaPen® Luxura, HumaPen® Savvio, HumaPen® Ergo II, Humalog® Pen
    • Novo Nordisk: FlexTouch®, NovoPen® 3, 4 and 5, InnoLet®, FlexPen®, Victoza®, NovoPen® Echo
    • Owen Mumford: Autopen® Classic, Autopen® Junior
    • Berlin Chemie: BerliPen® Areo, BerliPen® Junior

Best Practices In-Service Program for Rapid Implementation of Staff Training

ARKRAY offers live product in-servicing via webcam to demonstrate correct product usage and facilitate staff education in a timely manner.

We enable the execution of safe, reliable and accountable care to residents with diabetes in Long-Term Care Facilities.

Contact your ARKRAY Account Manager to schedule your Best Practices In-Service Program Training.

Instructions for Use: Assure® ID Standard Safety Pen Needle

Before injection, consult the pen injector device manual for proper use and control of insulin flow. If you are using for the first time and have questions, please contact your physician or healthcare professional.

Assure® ID Standard Safety Pen Needle Training Guide Video

Attaching the needle to the pen injection device

Step 1

Remove the seal from the safety pen needle by peeling back carefully and discard.

For your safety

  • Once the seal is removed, do not place fingers on the back end of the needle to avoid a needle stick.
  • Do not remove the ClearPrime safety cover from the safety pen needle until instructed to do so.

Step 2

Attach the safety pen needle securely to the pen injection device by twisting (as shown) clockwise until it is attached securely.

For your safety

  • Do not remove the ClearPrime™ safety cover as it serves as a safety shield to prevent a needle stick before injection. The cover should remain intact until ready to inject.

Priming the pen injection device

Step 3

Prime the pen injection device according to the instructions for the pen injection device. Note: you can see the priming drops through the ClearPrime safety cover.

For your safety

  • Do not remove the ClearPrime safety cover as it serves as a safety shield to prevent a needle stick before injection. The cover should remain intact until ready to inject and during transportation to the patient’s side.

Performing the injection

Step 4

When you are by the patient and ready to inject, remove the ClearPrime safety cover from the safety pen needle to expose the needle.

For your safety

  • Do not place your fingers on the front end of the needle to avoid a needle stick.

Step 5

Inject into the skin as recommended by your physician with or without a skin lift.

For your safety

  • Do not place your fingers on the front end of the needle to avoid a needle stick.

Step 6

Hold the injection for 5 to 10 seconds before withdrawing from the injection site as recommended by your physician to ensure delivery of the full dose and to prevent leakage of medication.

Step 7

Remove the needle from the injection site by lifting straight up from the injection site.

For your safety

  • Do not remove the needle at an angle.
  • The automatic safety shield will engage and cover the shielded needle when you lift the pen injection device from the patient’s skin.
  • Do not place fingers on the front end of the needle to prevent a needle stick.
  • Do not twist on the safety shield at any time.

Step 8

Attach the clear cover securely over the shielded needle by pushing the cover over the shielded needle and white barrel.

For your safety

  • Do not grasp or twist on the colored safety shield (turquoise–8mm) or the lower white barrel of the safety pen needle at any time to prevent damage to the safety mechanism and to prevent a needle stick.
  • Do not remove the needle before placing the cover back on the shielded needle.

Step 9

Remove the safety pen needle from the pen injection device by twisting counter-clockwise with your fingers on the clear cover. Immediately dispose of used safety pen needle in an approved sharps container and according to your sharps safety protocol.

For your safety

  • Do not grasp the needle by the back end at any time to prevent a needle stick.

Instructions for Use: Assure® ID DUO PRO and PRO Safety Pen Needle

Before injection, consult the pen injector device manual for proper use and control of insulin flow. If you are using for the first time and have questions, please contact your physician or healthcare professional.

 

Assure ID DUO PRO and PRO Safety Pen Needle Training Guide Video

 

Attaching the needle to the pen injection device

Assure ID DUO PRO and PRO Safety Pen Needles Instructions Step 1

Step 1

Remove the seal from the safety pen needle.

For your safety

  • Once the seal is removed, do not place fingers on the back end of the needle to avoid a needle stick.
  • Do not remove the ClearPrime safety cover from the safety pen needle until instructed to do so.
Assure ID DUO PRO and PRO Safety Pen Needles Instructions Step 2

Step 2

Attach the safety pen needle securely to the pen injector device by twisting clockwise until it stops. When using the Assure ID PRO safety pen needle, there will be no connection-end safety shield.

For your safety

  • Do not remove the ClearPrime safety cover as it serves as a safety shield to prevent a needle stick before injection. The cover should remain intact until ready to inject.

Priming the pen injection device

Assure ID DUO PRO and PRO Safety Pen Needles Instructions Step 3

Step 3

Prime the pen injector device according to the pen injector device instructions for use.

For your safety

  • Do not remove the ClearPrime safety cover as it serves as a safety shield to prevent a needle stick before injection. The cover should remain intact until ready to inject and during transportation to the patient’s side.

Performing the injection

Assure ID DUO PRO and PRO Safety Pen Needles Instructions Step 4

Step 4

When ready to inject, remove the safety cover from the safety pen needle to expose the needle.

For your safety

  • Do not place your fingers on the front end of the needle to avoid a needle stick.
Assure ID DUO PRO and PRO Safety Pen Needles Instructions Step 5

Step 5

Inject into the skin as recommended by your physician with or without a skin lift.

For your safety

  • Do not place your fingers on the front end of the needle to avoid a needle stick.
Assure ID DUO PRO and PRO Safety Pen Needles Instructions Step 6

Step 6

Hold the injection for 5 to 10 seconds before withdrawal as recommended by your physician to ensure delivery of the full dose and to prevent leakage of medication.
Assure ID DUO PRO and PRO Safety Pen Needles Instructions Step 7

Step 7

Remove the safety pen needle by lifting straight-up from the injection site. The patient-end safety mechanism is activated automatically when needle is withdrawn from the skin.

For your safety

  • Do not remove the needle at an angle.
  • The automatic patient-end safety shield will engage and cover the needle when you lift the pen injection device from the patient’s skin.
  • Do not place fingers on the front end of the needle to prevent a needle stick.
  • Do not twist on the safety shield at any time.
Assure ID DUO PRO and PRO Safety Pen Needles Instructions Step 8

Step 8

Attach the cover securely by pushing cover over the patient-end safety shield.

For your safety

  • Do not grasp or twist on the patient-end safety shield or the lower white barrel of the safety pen needle at any time to prevent damage to the safety mechanism and to prevent a needle stick.
  • Do not remove the needle before placing the cover back on the shielded needle.
Assure ID DUO PRO and PRO Safety Pen Needles Instructions Step 9

Step 9

Remove the safety pen needle from the pen injector device by twisting counter-clockwise. The pen connection-end safety shield will automatically engage when removed to assist in needlestick prevention. Dispose of in a sharps container. When using the Assure ID PRO safety pen needle, there will be no connection-end safety shield.

For your safety

  • The pen connection-end safety shield will automatically engage when the needle is removed from the pen injector device (DUO PRO only).
  • Do not grasp the needle by the back end at any time to prevent a needle stick.

Ordering Information

Assure® ID
DUO PRO and PRO Safety Pen Needle

Product Name Gauge Length (inch | mm) Qty. Case Qty. Product # UPC 015482 NDC 08317
Assure® ID DUO PRO Safety Pen Needle 31 3/16" | 5mm 100 1200 277531 277536 2775-31
Assure® ID PRO Safety Pen Needle 30 3/16" | 5mm 100 1200 276530 276539 2765-30

Assure® ID
Standard Safety Pen Needle

Product Name Gauge Length (inch. | mm) Qty. Case Qty. Product # UPC 015482 NDC 08317
Assure® ID Standard Safety Pen Needle 30 5/16" | 8mm 100 1200 278130 278304 2781-30

Information Request / Pen Needle Evaluation

If you would like to do an evaluation of the new Assure® ID Safety Pen Needles, please complete the form and an ARKRAY rep will follow-up with you quickly.

Fill out my online form.