Safe. Easy to use. Cost effective.

Assure ID Safety Pen Needles

Assure® ID Safety Pen Needles, from the brand you trust for safety and quality, offer features you require at a more cost-effective price than the market leaders.
Assure® ID Safety Pen Needles are now available in two models: Assure ID DUO PRO (with back-end shield) and Assure ID PRO (without back-end shield).

Features

Assure_ID-DUO_PRO-and-PRO-Features.png

SIZE

Assure_ID-DUO_Pro-and-Pro-size.png

5mm

Assure_ID-DUO_Pro-and-Pro-Cartons.jpg

Assure® ID
Safety Pen Needles

SAFETY BEFORE

Assure_ID-Before-After-ClearPrime.jpg

  • ClearPrime™ safety cover allows view of priming drops to ensure safe operation and delivery
  • Clear shield covers needle before injection to prevent needle exposure

SAFETY AFTER

Assure_ID_DUOPro_UnCapped_Unfired_Fired.png

  • Front-end safety shield to help protect against accidental needle sticks
  • Back-end safety shield to help protect against accidental needle sticks (Assure ID DUO PRO Safety Pen Needle)
  • Red indicator to signal the safety shield has activated

COMFORT

  • Needle lubrication designed to support smooth injections
  • Tri-bevel needle for comfortable injections

UNIVERSAL FIT

pen-Assure-ID-PRO.png

  • Fits securely to major pen devices from leading manufacturers, including:
  • -Sanofi Aventis: ClikSTAR®, SoloSTAR®, JuniorSTAR®
  • -Lilly: KwikPen®, HumaPen® Memoir, HumaPen® Luxura HD, HumaPen® Luxura, HumaPen® Savvio, HumaPen® Ergo II, Humalog® Pen
  • -Novo Nordisk: FlexTouch®, NovoPen® 3, 4 and 5, InnoLet®, FlexPen®, Victoza®, NovoPen® Echo
  • -Owen Mumford: Autopen® Classic, Autopen® Junior
  • -Berlin Chemie: BerliPen® Areo, BerliPen® Junior

Best Practices In-Service Program for Rapid Implementation of Staff Training

ARKRAY offers live product in-servicing via webcam to demonstrate correct product usage and facilitate staff education in a timely manner.

We enable the execution of safe, reliable and accountable care to residents with diabetes in Long-Term Care Facilities.

Contact your ARKRAY Account Manager to schedule your Best Practices In-Service Program Training.

Instructions for Use: Assure® ID DUO PRO and PRO Safety Pen Needle

Before injection, consult the pen injector device manual for proper use and control of insulin flow. If you are using for the first time and have questions, please contact your physician or healthcare professional.



Assure® ID DUO PRO/PRO Safety Pen Needle Training Guide Video

Attaching the needle to the pen injection device

step1

Step 1
Remove the seal from the safety pen needle.


For your safety
  • Once the seal is removed, do not place fingers on the back end of the needle to avoid a needle stick.
  • Do not remove the ClearPrime™ safety cover from the safety pen needle until instructed to do so.

Step_2.jpg

Step 2
Attach the safety pen needle securely to the pen injector device by twisting clockwise until it stops. When using the Assure ID PRO safety pen needle, there will be no connection-end safety shield.

For your safety
  • Do not remove the ClearPrime™ safety cover as it serves as a safety shield to prevent a needle stick before injection. The cover should remain intact until ready to inject.

Priming the pen injection device

Step_3.jpg

Step 3
Prime the pen injector device according to the pen injector device instructions for use.


For your safety
  • Do not remove the ClearPrime™ safety cover as it serves as a safety shield to prevent a needle stick before injection. The cover should remain intact until ready to inject and during transportation to the patient's side.

Performing the injection

Step_4.jpg

Step 4
When ready to inject, remove the safety cover from the safety pen needle to expose the needle.


For your safety
  • Do not place your fingers on the front end of the needle to avoid a needle stick.

Step_5.jpg

Step 5
Inject into the skin as recommended by your physician with or without a skin lift.


For your safety
  • Do not place your fingers on the front end of the needle to avoid a needle stick.

Assure-ID-DUO-PRO-and-PRO-Safety-Pen-Needles_Instructions_Step_6.jpg

Step 6
Hold the injection for 5 to 10 seconds before withdrawal as recommended by your physician to ensure delivery of the full dose and to prevent leakage of medication.

Step_7.jpg

Step 7
Remove the safety pen needle by lifting straight-up from the injection site. The patient-end safety mechanism is activated automatically when needle is withdrawn from the skin.


For your safety
  • Do not remove the needle at an angle.
  • The automatic patient-end safety shield will engage and cover the needle when you lift the pen injection device from the patient's skin.
  • Do not place fingers on the front end of the needle to prevent a needle stick.
  • Do not twist on the safety shield at any time.

Assure-ID-Safety-Pen-Needles_Instructions_Step_8.jpg

Step 8
Attach the cover securely by pushing cover over the patient-end safety shield.


For your safety
  • Do not grasp or twist on the patient-end safety shield or the lower white barrel of the safety pen needle at any time to prevent damage to the safety mechanism and to prevent a needle stick.
  • Do not remove the needle before placing the cover back on the shielded needle.

step9

Step 9
Remove the safety pen needle from the pen injector device by twisting counter-clockwise. The pen connection-end safety shield will automatically engage when removed to assist in needlestick prevention. Dispose of in a sharps container. When using the Assure ID PRO safety pen needle, there will be no connection-end safety shield.


For your safety
  • The pen connection-end safety shield will automatically engage when the needle is removed from the pen injector device (DUO PRO only).
  • Do not grasp the needle by the back end at any time to prevent a needle stick.

Instructions for Use: Assure® ID Standard Safety Pen Needle

Before injection, consult the pen injector device manual for proper use and control of insulin flow. If you are using for the first time and have questions, please contact your physician or healthcare professional.

Assure® ID Standard Safety Pen Needle Training Guide Video

Attaching the needle to the pen injection device

Assure-ID-Safety-Pen-Needles_Instructions_Step_1.jpg

Step 1
Remove the seal from the safety pen needle by peeling back carefully and discard.


For your safety
  • Once the seal is removed, do not place fingers on the back end of the needle to avoid a needle stick.
  • Do not remove the ClearPrime™ safety cover from the safety pen needle until instructed to do so.

Assure-ID-Safety-Pen-Needles_Instructions_Step_2.jpg

Step 2
Attach the safety pen needle securely to the pen injection device by twisting (as shown) clockwise until it is attached securely.


For your safety
  • Do not remove the ClearPrime™ safety cover as it serves as a safety shield to prevent a needle stick before injection. The cover should remain intact until ready to inject.

Priming the pen injection device

Step_3.jpg

Step 3
Prime the pen injection device according to the instructions for the pen injection device. Note: you can see the priming drops through the ClearPrime™ safety cover.


For your safety
  • Do not remove the ClearPrime™ safety cover as it serves as a safety shield to prevent a needle stick before injection. The cover should remain intact until ready to inject and during transportation to the patient's side.

Performing the injection

Assure-ID-Safety-Pen-Needles_Instructions_Step_5.jpg

Step 4
When you are by the patient and ready to inject, remove the ClearPrime™ safety cover from the safety pen needle to expose the needle.


For your safety
  • Do not place your fingers on the front end of the needle to avoid a needle stick.

Step_5.jpg

Step 5
Inject into the skin as recommended by your physician with or without a skin lift.


For your safety
  • Do not place your fingers on the front end of the needle to avoid a needle stick.

Step_6.jpg

Step 6
Hold the injection for 5 to 10 seconds before withdrawing from the injection site as recommended by your physician to ensure delivery of the full dose and to prevent leakage of medication.

Assure-ID-Safety-Pen-Needles_Instructions_Step_8.jpg

Step 7
Remove the needle from the injection site by lifting straight up from the injection site.


For your safety
  • Do not remove the needle at an angle.
  • The automatic safety shield will engage and cover the shielded needle when you lift the pen injection device from the patient's skin.
  • Do not place fingers on the front end of the needle to prevent a needle stick.
  • Do not twist on the safety shield at any time.

Step%209.png

Step 8
Attach the clear cover securely over the shielded needle by pushing the cover over the shielded needle and white barrel.


For your safety
  • Do not grasp or twist on the colored safety shield (turquoise-8mm) or the lower white barrel of the safety pen needle at any time to prevent damage to the safety mechanism and to prevent a needle stick.
  • Do not remove the needle before placing the cover back on the shielded needle.

Step%209.png

Step 9
Remove the safety pen needle from the pen injection device by twisting counter-clockwise with your fingers on the clear cover. Immediately dispose of used safety pen needle in an approved sharps container and according to your sharps safety protocol.


For your safety
  • Do not grasp the needle by the back end at any time to prevent a needle stick.

Ordering Information

Assure-ID-DUO-Shield-Safety-Pen-Needle.png

Assure® ID DUO PRO and PRO Safety Pen Needle

Assure® ID DUO PRO Safety Pen Needle
Gauge 31
Length (inch|mm) 3/16"|5mm
Qty 100
Case Qty. 1200
Product # 277531
UPC 015482 277536
NDC 08317 2775-31
Assure® ID PRO Safety Pen Needle
Gauge 30
Length (inch|mm) 3/16"|5mm
Qty 100
Case Qty. 1200
Product # 276530
UPC 015482 276539
NDC 08317 2765-30

Assure-ID-Standard-Safety-Pen-Needle.png

Assure® ID Standard Safety Pen Needle

Product Name:Assure® ID Standard Safety Pen Needle
Gauge 30
Length (inch|mm) 5/16"|8mm
Qty 100
Case Qty. 1200
Product # 278130
UPC 015482 278304
NDC 08317 2781-30

Information Request / Pen Needle Evaluation

If you would like to do an evaluation of the new Assure® ID Safety Pen Needles, please complete the form and an ARKRAY rep will follow-up with you quickly.